<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>The Poison Review &#187; Alcohol</title>
	<atom:link href="http://www.thepoisonreview.com/category/toxicology/alcohol/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.thepoisonreview.com</link>
	<description>&#34;Poison is everything and no thing is without poison&#34; - Paracelsus</description>
	<lastBuildDate>Sun, 05 Feb 2012 22:36:49 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>Breath Alcohol Analyzer Mistakes Methanol Poisoning for Alcohol Intoxication</title>
		<link>http://www.thepoisonreview.com/2010/01/04/breath-alcohol-analyzer-mistakes-methanol-poisoning-for-alcohol-intoxication/</link>
		<comments>http://www.thepoisonreview.com/2010/01/04/breath-alcohol-analyzer-mistakes-methanol-poisoning-for-alcohol-intoxication/#comments</comments>
		<pubDate>Tue, 05 Jan 2010 04:05:11 +0000</pubDate>
		<dc:creator>Steve Aks</dc:creator>
				<category><![CDATA[Alcohol]]></category>
		<category><![CDATA[breath alcohol]]></category>
		<category><![CDATA[ethanol]]></category>

		<guid isPermaLink="false">http://www.thepoisonreview.com/?p=532</guid>
		<description><![CDATA[<p>4 out of 5 stars</p>
<p><strong>BREATH ALCOHOL ANALYZER MISTAKES METHANOL POISONING FOR ALCOHOL INTOXICATION Caravati EM et al. <em>Ann Emerg Med</em> 2009 Oct 13 [epub ahead of print]</strong></p>
<p><a href="http://www.ncbi.nlm.nih.gov/pubmed/19833410?itool=EntrezSystem2.PEntrez.Pubmed.Pubmed_ResultsPanel.Pubmed_RVDocSum&#38;ordinalpos=1">Abstract</a></p>
<p>This very interesting case report describes a false positive breath ethanol test erroneously indicating 0.288 g/210 L breath ethanol.  In the hospital blood ethanol was not detected; however, the serum methanol &#8230;</p>]]></description>
			<content:encoded><![CDATA[<p>4 out of 5 stars</p>
<p><strong>BREATH ALCOHOL ANALYZER MISTAKES METHANOL POISONING FOR ALCOHOL INTOXICATION Caravati EM et al. <em>Ann Emerg Med</em> 2009 Oct 13 [epub ahead of print]</strong></p>
<p><a href="http://www.ncbi.nlm.nih.gov/pubmed/19833410?itool=EntrezSystem2.PEntrez.Pubmed.Pubmed_ResultsPanel.Pubmed_RVDocSum&amp;ordinalpos=1">Abstract</a></p>
<p>This very interesting case report describes a false positive breath ethanol test erroneously indicating 0.288 g/210 L breath ethanol.  In the hospital blood ethanol was not detected; however, the serum methanol concentration was 589 mg/dl.  The breath test was done on an Intoxilyzer® 5000EN (CMI Inc). This is a rarely observed false positive result obtained by a breath alcohol analyzer.</p>
<p>The theory behind the false positive is that if a volatile compound has enough vapor pressure to pass from the blood into the breath, and absorbs infrared light at the same wavelength regions as the ethanol molecule,  a false reading may result.   This is a well written report with a good discussion of the breath analyzer.</p>
<p><a href="http://www.ncbi.nlm.nih.gov/pubmed/19833410?itool=EntrezSystem2.PEntrez.Pubmed.Pubmed_ResultsPanel.Pubmed_RVDocSum&amp;ordinalpos=1"></a></p>
<p><a href="http://www.ncbi.nlm.nih.gov/pubmed/19833410?itool=EntrezSystem2.PEntrez.Pubmed.Pubmed_ResultsPanel.Pubmed_RVDocSum&amp;ordinalpos=1"></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.thepoisonreview.com/2010/01/04/breath-alcohol-analyzer-mistakes-methanol-poisoning-for-alcohol-intoxication/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>